Cable Accessories
Matsuo Current Fuse JAG N Series is designed for circuit protection against excessive current in portable electronic equipment, electric circuit around battery, etc. because the demand for HV and EV are increasing.
Wire material is adopted for fuse element, and the performance against pulse resistance is increased in spite of compact design. Also, the ecology design of Current Fuse JAG N Series is environmentally friendly because of complete lead-free.
Matsuo Current Fuse JAG N Series – Features
Our original construction design has excellent fusing and cutting characteristics.
Especially, performance against pulse resistance is excellent since wire material is used for fuse element.
Surface temperature rise is 75°C or less when applying rated current for fusing. This gives less influence to the peripheral units.
Resistance to soldering heat: Reflow or flow soldering 10 seconds at 260 °C.
Our original terminal construction makes almost no occurrence of Tombstone phenomenon.
Small size of 3216 (3. 2×1. 6×1. 6 mm).
Suitable for automatic mounting.
Precise dimensions allows high-density mounting and symmetrical construction of terminals provide “Self-Alignment”.
Complete lead-free, bromine-free.
Due to its high reliability, JAG N series are suitable for circuit designs for automotive interiors.
Rating
Type JAG N series
Rated Current 0.63-0.8-1.0-1.25-1.6-2.0-2.5-3.15-4.0A
Rated Voltage 32、72
96VDC
Voltage Drop 240mV max
Insulation Resistance 1000MΩ or more
Fusing Characteristics Fusing within 1 minutes if the current is 200% of rated current.
Blocking Characteristic Breaking voltage:Rated voltgae
* Technical Data subject to change without notice.
MGA Trading, Dammam, maintains a technical advisory service.
Contact us: +966 13 882 1111 / +966 13 831 1116
| Type | JAG N series |
|---|---|
| Rated Current | 0.63-0.8-1.0-1.25-1.6-2.0-2.5-3.15-4.0A |
| Rated Voltage | 32、72 96VDC |
| Voltage Drop | 240mV max |
| Insulation Resistance | 1000MΩ or more |
| Fusing Characteristics | Fusing within 1 minutes if the current is 200% of rated current. |
| Blocking Characteristic | Breaking voltage:Rated voltgae Breaking current:50A |