CCG D1EX Captive Component Cable Gland (0519) is a Hazardous Area Glanding Device for Steel Wire Armoured Cable. Suitable for indoors, outdoors, Group II, III, Zone 1, 2, 20, 21 and 22 hazardous areas.
CCG Part Numbers: 051900-16, 051900, 0519-0, 051901, 051922, 051902, 051933, 051903, 051944, 051904, 051955, 051905, 051966, 051906, 051977, 051907, 051908, 051999, 051909, 051810, 051911, 051912, 051913
Features & Benefits
For indoors, outdoors, Group II, III, Zone 1, 2, 20, 21 and 22 hazardous areas.
Two-piece handling, no loose parts.
A freely rotating captive cone and inspectable cone ring provides an armour clamp and earth bond on steel wire armour.
A specially formulated elastomeric seal for Built-in Safety™, seals on the inner sheath of the cable IP65/66/68.
Precision manufactured from high-quality brass (Marine Grade Electroless Nickel Plated™).
Supplied with a thread sealing gasket (parallel threads only).
Type: D1EX
Equipment Protection Levels: Ex db IIC, Ex eb IIC, Ex nR IIC, Ex ta IIIC
Gland Material: Brass (Marine Grade Electroless Nickel Plated™)
Seal Material: Standard Thermoset Elastomer or Extreme Temperature Seals
Sealing Gasket Material: HDPE, Nylon 66 or PTFE
Cable Type: Steel Wire Armour
Armour Clamping: Rotating Captive Cone and Inspectable Cone Ring
Sealing Area: Inner Sheath
Optional Accessories: Adaptor, Reducer, Earth Tag, Locknut, Serrated Washer and Shroud
Note: The installer should ensure that the materials are suitable for the installation environment.
Installation Standards
IEC/BS EN
IECEx
ATEX
UKEX
INMETRO (Brazil)
TR CU (Russia)
SANS
Ingress Protection
Deluge Protection
Corrosion Protection
Marine ABS
DNV-GL
EMC Compatible
A Hazardous Area is one in which there is potential for an explosion of gases, vapours, mists or dust or a combination of these. Such locations are petrochemical plants, offshore oil rigs, fuel filling stations, timber mills, coal mines, flour mills, paint spray booths, sewerage treatment plants, hospitals, explosive magazines and more.
Special precautions must be taken for the design, manufacture, installation and use of equipment and cable glands in such hazardous areas. Persons involved in selecting installing and maintaining electrical equipment for use in hazardous areas should be competently trained, have a full understanding of what a hazardous area is and have knowledge of the equipment protection levels and the installation standards involved.
Additional Technical Data on CCG D1EX Captive Component Cable Gland (0519) Part Numbers can be found on the table below. For Conforming Standards & Certificates as well as Fitting Instructions, please advise PDF File.
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
| Product Code | Gland Size Ref. |
|---|---|
| Product Code051900-16 | Gland Size Ref.00-16ss |
| Product Code051900 | Gland Size Ref.00-20ss |
| Product Code0519-0 | Gland Size Ref.0-20s |
| Product Code051901 | Gland Size Ref.1-20 |
| Product Code051922 | Gland Size Ref.2s-25s |
| Product Code051902 | Gland Size Ref.2-25 |
| Product Code051933 | Gland Size Ref.3s-32s |
| Product Code051903 | Gland Size Ref.3-32 |
| Product Code051944 | Gland Size Ref.4s-40s |
| Product Code051904 | Gland Size Ref.4-40 |
| Product Code051955 | Gland Size Ref.5s-50s |
| Product Code051905 | Gland Size Ref.5-50 |
| Product Code051966 | Gland Size Ref.6s-63s |
| Product Code051906 | Gland Size Ref.6-63 |
| Product Code051977 | Gland Size Ref.7s-75s |
| Product Code051907 | Gland Size Ref.7-75 |
| Product Code051908 | Gland Size Ref.8-80 |
| Product Code051999 | Gland Size Ref.9s-90s |
| Product Code051909 | Gland Size Ref.9-90 |
| Product Code051910 | Gland Size Ref.10-100 |
| Product Code051911 | Gland Size Ref.11-115 |
| Product Code051912 | Gland Size Ref.12-120 |
| Product Code051913 | Gland Size Ref.13-130 |
| All dimensions except NPT are in mm. Intermediate thread sizes are available on request. NPT threads should be tightened ‘wrench tight’. |