MGA Trading Logo
  • About
  • Contact
  • Brands
  • Downloads
  • News
Cable Accessories
Cable Management & Protection
Crimping Systems
Earthing & Lightning Protection
Industry-Specific Solutions
LV, MV & HV Tools

Core Industries

  • Electrical
  • Industrial
  • Mechanical
  • Construction
  • Projects

World-Class Brands

  • Prysmian Group
  • Dutchclamp
  • Elpress
  • Anaconda
  • Schnabl
  • Silver Fox
  • 3M
  • SACS
  • Axis
  • Home
  • About
  • Downloads
  • Tool Hire
  • Tool Support
  • Training Centre
  • News
  • Careers
  • Terms and Conditions
  • Cookies Privacy Policy
  • Customers Privacy Policy
  • Contact us
MGA Logo

MGA TRADING

Al Osais Tower, King Fahd Road,

Al Khobar, 31952,

Kingdom of Saudi Arabia

t: +966 13 882 1111

e: info@mgat.com

Copyright © 2026 MGAT

Home>Cable Accessories>Separable Connectors>Nexans Euromold Separable Connectors

Nexans Euromold 804PB Coupling Connector

Nexans Euromold 804PB Coupling Connector
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

Product overview

Nexans Euromold 804PB Separable Coupling Connector

Nexans Euromold 804PB Separable Coupling Connector is a coupling connector (bolted type) for dual arrangement. Designed to be used with 480TB, 484TB and 489TB Separable Tee Connectors and meets the requirements of CENELEC HD 629,1. Can also be installed on any 8-series coupling connector for a multiple cable arrangement.

Type 804PB Part Numbers: 804PB/G, K804PB/G, M804PB/G, P804PB/G.

Euromold 804PB is a bolted separable coupling connector specified to terminate and connect medium/high voltage cables in the following voltage classes:

6/10 (12kV)

6.35/11 (12kV)

8.7/15 (17.5kV)

12/20 (24kV)

12.7/22 (24kV)

18/30 (36kV)

19/33 (36kV)

20.8/36 (42kV)

Technical Characteristics

A thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel.

Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.

Specification & Design

The 804PB separable connector meets the requirements of CENELEC HD 629,1.

Euromold

Type 804PB Voltage

Um Current

Ir Conductor Size

Min-Max

804PB/G 12 kV 1250 Amps 240-630 mm2

K804PB/G 24 kV 1250 Amps 240-630 mm2

M804PB/G 36 kV 1250 Amps 240-630 mm2

P804PB/G 42 kV 1250 Amps 240-630 mm2

Separable connector comprising:

Interface designed to fit 480TB, 484TB and 489TB connectors

Contact rod for 804PB

Conductor contact

Conductive EPDM insert

Conductive EPDM jacket

Insulating EPDM layer moulded between the insert and the jacket

Cable reducer

Conductive EPDM cap

Basic insulating plug (with VD point)

Earthing lead

The screen break design enables cable outer sheath testing without removing or dismantling the connector.

804PB Coupling Connector Kit Contents

The complete (K)(M)(P)804PB/G coupling connector kit comprises 3 x the following components. The kit also comprises silicone grease, field control mastic, gloves, wipers, roll adhesive tape, installation instructions and crimp chart.

For Ordering Instructions and Part Number Selection Table of Nexans Euromold 804PB Separable Coupling Connector (804PB/G, K804PB/G, M804PB/G, P804PB/G), please refer to the Technical Data Table Below. For additional General and Technical Information, download the PDF files.

FREE Technical Advisory Service

E-Tech Components UK Ltd maintains a free technical advisory service.

Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Download PDF: 804PB Separable Coupling Connector

Interested in this Product?

Contact Us+966 13 831 1116

Technical Data

Euromold Type 804PBVoltage Um
Euromold Type 804PB804PB/GVoltage Um12 kV
Euromold Type 804PBK804PB/GVoltage Um24 kV
Euromold Type 804PBM804PB/GVoltage Um36 kV
Euromold Type 804PBP804PB/GVoltage Um42 kV
ORDERING INSTRUCTIONS FOR (K)(M)(P)804PB To order the coupling connector, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV and a 'P' for use up to 42 kV. Example: The copper wire screened cable is 36 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 37 mm. Order 3 x M804PB/G-S-32-240BI2 coupling connector kit.
PART NUMBERDIAMETER OVER CORE INSULATION MIN
PART NUMBER3 x 804PB/G-S-22-XDIAMETER OVER CORE INSULATION MIN23.5 mm
PART NUMBER3 x 804PB/G-S-27-XDIAMETER OVER CORE INSULATION MIN28.5 mm
PART NUMBER3 x 804PB/G-S-32-XDIAMETER OVER CORE INSULATION MIN34 mm
PART NUMBER3 x 804PB/G-S-37-XDIAMETER OVER CORE INSULATION MIN39 mm
PART NUMBER3 x 804PB/G-S-43-XDIAMETER OVER CORE INSULATION MIN45.5 mm
TABLE X - CONNECTORS SUITABLE FOR COPPER & ALUMINIUM CABLES
CONDUCTOR SIZEAlu Conductor DIN Hexagonal
CONDUCTOR SIZE240 mm2Alu Conductor DIN Hexagonal240BI2
CONDUCTOR SIZE300 mm2Alu Conductor DIN Hexagonal300BI2
CONDUCTOR SIZE400 mm2Alu Conductor DIN Hexagonal400BI2
CONDUCTOR SIZE500 mm2Alu Conductor DIN Hexagonal500BI2
CONDUCTOR SIZE630 mm2Alu Conductor DIN Hexagonal-