Nexans Euromold 800PB Separable Coupling Connector is a coupling connector (bolted type) for dual arrangement. Designed to be used with 480TB, 484TB and 489TB Separable Tee Connectors and meets the requirements of CENELEC HD 629,1. Can also be installed on any 8-series coupling connector for a multiple cable arrangement.
Type 800PB Part Numbers: 800PB/G, K800PB/G, M800PB/G, P800PB/G.
Euromold 800PB is a bolted separable coupling connector specified to terminate and connect medium/high voltage cables in the following voltage classes:
6/10 (12kV)
6.35/11 (12kV)
8.7/15 (17.5kV)
12/20 (24kV)
12.7/22 (24kV)
18/30 (36kV)
19/33 (36kV)
20.8/36 (42kV)
Technical Characteristics
A thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel.
Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.
The 800PB separable connector meets the requirements of CENELEC HD 629,1.
Euromold
Type 800PB Voltage
Um Current
Ir – C1 Bushing Current
Ir – C2 Bushing Conductor Size
Min-Max
800PB/G 12 kV 630 Amps 1250 Amps 16-300 mm2
K800PB/G 24 kV 630 Amps 1250 Amps 16-300 mm2
M800PB/G 36 kV 630 Amps 1250 Amps 50-300 mm2
Interface designed to fit 480TB, 484TB and 489TB connectors
Contact rod for 800PB
Conductor contact
Conductive EPDM insert
Conductive EPDM jacket
Insulating EPDM layer moulded between the insert and the jacket
Cable reducer
Conductive EPDM cap
Basic insulating plug
The screen break design enables cable outer sheath testing without removing or dismantling the connector.
The complete (K)(M)(P)800PB/G coupling connector kit comprises 3 x the following components. The kit also comprises silicone grease, installation cone, gloves, wipers, roll adhesive tape and installation instructions.
For Ordering Instructions and Part Number Selection Table of Nexans Euromold 800PB Separable Coupling Connector (800PB/G, K800PB/G, M800PB/G, P800PB/G), please refer to the Technical Data Table Below. For additional General and Technical Information, download the PDF files.
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
| Euromold Type 800PB | Voltage Um |
|---|---|
| Euromold Type 800PB800PB/G | Voltage Um12 kV |
| Euromold Type 800PBK800PB/G | Voltage Um24 kV |
| Euromold Type 800PBM800PB/G | Voltage Um36 kV |
| Euromold Type 800PBP800PB/G | Voltage Um42 kV |
| ORDERING INSTRUCTIONS FOR (K)(M)(P)800PB To order the coupling connector, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV and a 'P' for use up to 42 kV. Example: The copper wire screened cable is 24 kV, 185 mm2 compact stranded copper with a diameter over core insulation of 27,5 mm. Order 3 x K800PB/G-018-95.300UN5 coupling connector kit. | |
| PART NUMBER | DIAMETER OVER CORE INSULATION MIN |
| PART NUMBER3 x 800PB/G-011-X | DIAMETER OVER CORE INSULATION MIN12 mm |
| PART NUMBER3 x 800PB/G-015-X | DIAMETER OVER CORE INSULATION MIN16 mm |
| PART NUMBER3 x 800PB/G-018-X | DIAMETER OVER CORE INSULATION MIN19 mm |
| PART NUMBER3 x 800PB/G-021-X | DIAMETER OVER CORE INSULATION MIN22 mm |
| PART NUMBER3 x 800PB/G-027-X | DIAMETER OVER CORE INSULATION MIN28.5 mm |
| TABLE X - CONNECTORS SUITABLE FOR COPPER & ALUMINIUM CABLES | |
| CONDUCTOR SIZE | ALU & CU CONDUCTOR BOLTED |
| CONDUCTOR SIZE16 mm2 | ALU & CU CONDUCTOR BOLTED16.95UN5 |
| CONDUCTOR SIZE25 mm2 | ALU & CU CONDUCTOR BOLTED16.95UN5 |
| CONDUCTOR SIZE35 mm2 | ALU & CU CONDUCTOR BOLTED16.95UN5 |
| CONDUCTOR SIZE50 mm2 | ALU & CU CONDUCTOR BOLTED16.95UN5 |
| CONDUCTOR SIZE70 mm2 | ALU & CU CONDUCTOR BOLTED16.95UN5 |
| CONDUCTOR SIZE95 mm2 | ALU & CU CONDUCTOR BOLTED16.95UN5 |
| CONDUCTOR SIZE120 mm2 | ALU & CU CONDUCTOR BOLTED- |
| CONDUCTOR SIZE150 mm2 | ALU & CU CONDUCTOR BOLTED- |
| CONDUCTOR SIZE185 mm2 | ALU & CU CONDUCTOR BOLTED- |
| CONDUCTOR SIZE240 mm2 | ALU & CU CONDUCTOR BOLTED- |
| CONDUCTOR SIZE300 mm2 | ALU & CU CONDUCTOR BOLTED- |