MGA Trading Logo
  • About
  • Contact
  • Brands
  • Downloads
  • News
Cable Accessories
Cable Management & Protection
Crimping Systems
Earthing & Lightning Protection
Industry-Specific Solutions
LV, MV & HV Tools

Core Industries

  • Electrical
  • Industrial
  • Mechanical
  • Construction
  • Projects

World-Class Brands

  • Prysmian Group
  • Dutchclamp
  • Elpress
  • Anaconda
  • Schnabl
  • Silver Fox
  • 3M
  • SACS
  • Axis
  • Home
  • About
  • Downloads
  • Tool Hire
  • Tool Support
  • Training Centre
  • News
  • Careers
  • Terms and Conditions
  • Cookies Privacy Policy
  • Customers Privacy Policy
  • Contact us
MGA Logo

MGA TRADING

Al Osais Tower, King Fahd Road,

Al Khobar, 31952,

Kingdom of Saudi Arabia

t: +966 13 882 1111

e: info@mgat.com

Copyright © 2026 MGAT

Home>Cable Accessories>Separable Connectors>Nexans Euromold Separable Connectors

Nexans Euromold 400LR Separable Elbow Connector

Nexans Euromold 400LR Separable Elbow Connector
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

Product overview

Nexans Euromold 400LR Separable Elbow Connector

Nexans Euromold 400LR Separable Elbow Connector with 400A Current Rating is an elbow connector designed for Interface B and covers voltages from 11/12kV to 33/36kV with a maximum conductor size of 240sqmm. The separable connector connects polymeric insulated cable to equipment (transformers, switchgear, motors, etc.) and meets the requirements of CENELEC HD 629,1.

Type 400LR Part Numbers: 400LR/G, K400LR/G, M400LR/G.

Euromold 400LR is a screened separable elbow connector specified to terminate and connect medium/high voltage cables onto Interface B bushings in the following voltage classes:

6/10 (12kV)

6.35/11 (12kV)

8.7/15 (17.5kV)

12/20 (24kV)

12.7/22 (24kV)

18/30 (36kV)

19/33 (36kV)

Technical Characteristics

The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel.

Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.

Specification & Design

Euromold

Type 400LR Voltage

Um Current

Ir Conductor Size

Min Conductor Size

Max

400LR/G 12 kV 400 Amps 50 240

K400LR/G 24 kV 400 Amps 25 240

M400LR/G 36 kV 400 Amps 35 185

Separable connector comprising:

Conductive EPDM insert.

Conductive EPDM jacket.

Insulating EPDM layer moulded between the insert and the jacket.

Type B – interface as described by CENELEC EN 50180 and 50181.

Conductor connector.

Cable reducer.

Earthing lead.

VD point.

Conductive rubber cap.

The screen break design enables cable outer sheath testing without removing or dismantling the connector.

400LR Elbow Connector Kit Contents

The complete (K)(M)400LR/G elbow connector kit comprises the following components. The kit also comprises silicon grease, gloves, wipers and installation instructions.

For Ordering Instructions and Part Number Selection Table of Nexans Euromold 400LR Elbow Connectors (400LR/G, K400LR/G, M400LR/G), please refer to the Technical Data Table Below. For additional General and Technical Information, download the PDF files.

FREE Technical Advisory Service

E-Tech Components UK Ltd maintains a free technical advisory service.

Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Download PDF: 400LR Separable Elbow Connector Datasheet

Interested in this Product?

Contact Us+966 13 831 1116

Technical Data

Euromold Type 400LRVoltage Um
Euromold Type 400LR400LR/GVoltage Um12 kV
Euromold Type 400LRK400LR/GVoltage Um24 kV
Euromold Type 400LRM400LR/GVoltage Um36 kV
ORDERING INSTRUCTIONS FOR (K)(M)400LR/G To order the elbow connector, select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 24 kV and add an 'M' for use up to 36 kV. Example: The copper wire screened cable is 24 kV, 185 mm2 stranded copper with a diameter over core insulation of 27.5 mm. Order a K400LR/G-018-95.240UN5 elbow connector kit.
PART NUMBERDIAMETER OVER CORE INSULATION MIN
PART NUMBER400LR/G-011-XDIAMETER OVER CORE INSULATION MIN12 mm
PART NUMBER400LR/G-015-XDIAMETER OVER CORE INSULATION MIN16 mm
PART NUMBER400LR/G-018-XDIAMETER OVER CORE INSULATION MIN19 mm
PART NUMBER400LR/G-021-XDIAMETER OVER CORE INSULATION MIN22 mm
PART NUMBER400LR/G-027-XDIAMETER OVER CORE INSULATION MIN28.5 mm
TABLE X - ALUMINIUM & COPPER CONDUCTOR
CONDUCTOR SIZEBOLTED
CONDUCTOR SIZE25 mm2BOLTED25.95UN5
CONDUCTOR SIZE35 mm2BOLTED25.95UN5
CONDUCTOR SIZE50 mm2BOLTED25.95UN5
CONDUCTOR SIZE70 mm2BOLTED25.95UN5
CONDUCTOR SIZE95 mm2BOLTED25.95UN5
CONDUCTOR SIZE120 mm2BOLTED-
CONDUCTOR SIZE150 mm2BOLTED-
CONDUCTOR SIZE185 mm2BOLTED-